Sigua Rodriguez, Eder AlbertoEder AlbertoSigua RodriguezHemerson de Moraes, PauloPauloHemerson de MoraesRangel Goulart, DouglasDouglasRangel GoulartArmini Caldas, RicardoRicardoArmini CaldasOlate, SergioSergioOlatede Albergaria-Barbosa, Jose RicardoJose Ricardode Albergaria-BarbosaBarão, Valentim Adelino RicardoValentim Adelino RicardoBarão2026-10-192026-10-192018-09-2610.1016/j.jcms.2018.09.011https://repositorio.unicoc.edu.co/handle/SII-Unicoc/322930718216Objetivo: Comparar las características mecánicas de cinco técnicas para la fijación funcionalmente estable de osteotomía de rama sagital simulada con 10 mm de avance y evaluar el torque de inserción del tornillo. Materiales y métodos: Cincuenta hemimandíbulas de poliuretano con osteotomía de rama dividida sagital y que contienen un avance de 10 mm fijadas y distribuidas de la siguiente manera: Grupo de placas 3D personalizadas: 1 miniplaca 3D personalizada; Grupo de placas de 4 orificios: 2 miniplacas con 4 orificios; Grupo de placas de 6 orificios: 2 miniplacas de 6 orificios; Grupo Híbrido: 1 miniplaca plana de 4 agujeros y 1 tornillo bicortical; y grupo de tornillos bicorticales: 3 tornillos bicorticales. Realizamos una prueba mecánica utilizando carga lineal vertical con una velocidad de desplazamiento de 1 mm/min en una máquina de prueba universal y evaluamos el par de inserción del tornillo con una llave dinamométrica digital. Resultados: Las medias de resistencia para los desplazamientos de 1, 3 y 5 mm se determinaron mediante un análisis de varianza (ANOVA) de una vía seguido de la prueba post hoc de Tukey. Se observaron diferencias estadísticamente significativas solo para el desplazamiento de 5 mm (F = 3,36; p = 0,01). Hubo una diferencia entre los grupos 4-H2P y HG (p = 0,04). Conclusión: La miniplaca personalizada, los métodos de fijación con tres tornillos bicorticales o con dos miniplacas rectas de 4 o 6 agujeros, ofrecen una resistencia mecánica similar adecuada para la fijación.Purpose: To compare the mechanical characteristics of five techniques for the functionally stable fixation of simulated sagittal split ramus osteotomy with 10 mm of advancement and to evaluate the screw insertion torque. Materials and methods: Fifty polyurethane hemimandibles with sagittal split ramus osteotomy and containing an advancement of 10 mm fixed and distributed as follows: Customized 3D Plate Group: 1 customized 3D miniplate; 4-Hole Plate Group: 2 miniplates with 4 holes; 6-Hole Plate Group: 2 miniplates with 6 holes; Hybrid Group: 1 flat miniplate with 4 holes and 1 bicortical screw; and Bicortical Screw Group: 3 bicortical screws. We conducted a mechanical test using vertical linear loading with a displacement velocity of 1 mm/min on a universal testing machine and assessed the screw insertion torque using a digital torque wrench. Results: The means of strength for the 1-, 3- and 5-mm displacements were determined by a one-way analysis of variance (ANOVA) followed by the post hoc Tukey test. Statistically significant differences were observed only for the 5-mm displacement (F ¼ 3.36; p ¼ 0.01). There was a difference between the 4-H2P and HG groups (p ¼ 0.04). Conclusion: The customized miniplate, the fixation methods with three bicortical screws, or with two straight miniplates with either 4 or 6 holes, all offer a similar mechanical resistance suitable for fixation.6 pp.application/pdfenMandíbulaRama dividida sagitalDiseño asistido por ordenadorOsteotomíaEstudios primariosComparative evaluation of different fixation techniques of the sagittal split ramus osteotomy in 10 mm advancements: Mechanical testing and screw insertion torqueEvaluación comparativa de diferentes técnicas de fijación del sagital osteotomía de rama dividida en avances de 10 mm: pruebas mecánicas y torque de inserción del tornillojournal articleMandibleOsteotomySagittal split ramusComputer-aided designclosedAccess